Part Number Hot Search : 
00TTS LR120 SOT533 KIA70 IRSF3031 BR305 HSK277 ZFMG07A2
Product Description
Full Text Search
 

To Download 10PCVXXX Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
  model numbers 7pcv2415 7pcv2425 10pcv2415 10pcv2425 10pcv2450 10pcv2475 10pcv2490 output specifications ? operating voltage (47-63 hz) [vrms] 100-240 100-240 100-240 100-240 100-240 max. load current range [arms] .15-15 .15-25 .15-50 .15-75 .15-90 transient overvoltage [vpk] 600 600 600 600 600 max. surge current, (1 cycle) [apk] 150 250 625 1000 1200 max. off-state leakage current @ rated voltage [ma] 10 15 20 20 20 maximum i 2 t for fusing (8.3 msec) [a 2 sec] 94 260 1620 4150 6000 maximum voltage drop (100% on) [vpk] 1.6 1.6 1.6 1.6 1.6 minimum off-state dv/dt [v/sec] 200 200 200 200 200 power factor (min.) with max. load 0.5 0.5 0.5 0.5 0.5 input specifications ? 7pcv24xx 10pcv24xx control voltage range 2-7 vdc 2-10 vdc typical input current @ 5 vdc 4 ma 4 ma general notes ? all parameters at 25o c unless otherwise specified.  operates at 60hz & 50hz  internal snubber  industry standard package  control circuit requires no adjustment or calibration fastfax document no. 204 series pcv. rev. 041902 page 1 of 2 the pcv series proportional controllers are self contained power control mod- ules integrating a complete phase fired logic control system and a solid state relay in the same standard package. typical applications include heaters, vibratory feeders and tungsten lamps. series pcv analog input power controller typical applications  industrial temperature controllers  light dimming  vibratory feeders  resistive heating elements  conveyor speed control unsuitable applications the pcv is not suitable for some load applications including, but not limited to the following:  ac motor control  three phase motors  transformers requiring pure sine wave input  zero crossing applications please contact crydom ? s application engineering department for additional information and specific application questions. 100 80 60 40 20 0 2.5 4.5 5.5 3.5 6.5 7.5 8.5 9.5 input voltage percentage on percentage on vs. input voltage 50 hz 60 hz 50 hz 60 hz 50 hz 60 hz 50 hz 60 hz 50 hz 60 hz 50 hz 60 hz 50 hz 60 hz 50 hz 60 hz ? 2002 crydom corp, specifications subject to change without notice. for recommended applications and more information contact: usa: sales support (877) 502-5500 tech support (877) 702-7700 fax (619) 710-8540 crydom corp, 2320 paseo de las americas, ste. 201, san diego, ca 92154 email : sales@crydom.com web site: http://www.crydom.com uk: +44 (0)1202 365070  fax +44 (0)1202 365090 crydom international ltd., 7 cobham road, ferndown industrial estate, ferndown, dorset bh21 7pe, email : intsales@crydom.com. germany: +49 (0)180 3000 506
1.87 (47.5) .78 (19.8) 2.30 (58.4) 1.70 (43.2) .90 (22.9) .45 (11.4) 1.10 (27.9) 8-32 terminal (2 places ) 1.00 (25.4) 6-32 terminal (2 places) 1.80 (45.7) solid-state relay 12 output 3 4 + -- input mounting hole/slot 0.17 (4.3) dia. base plate .125 (3.2) g e n e r a l spe c i f i c a t ion s dielectric strength, signal to load 2500 vrms dielectric strength, signal to base 2500 vrms ambient operating temperature range -30 to 80?c ambient storage temperature range -40 to 125?c m e c hani c a l spe c i f i c a t ion s weight: (typical) 3.5 oz. (100g) encapsulation: thermally conductive epoxy terminals: screws and saddle clamps furnished, unmounted s erie s p c v analog input power controller 30 20 10 25 15 5 0 510 2025 15 20 40 60 80 load current [arms] max ambient temp. [ ? c] power dissipation 95 120 base plate temp [ ? c] 25a 1 ? c/w 100 110 3 ? c/w no heatsink 60 40 20 0 10 20 40 50 30 20 40 60 80 load current [arms] max ambient temp. [ ? c] power dissipation 90 base plate temp [ ? c] 50a 2 ? c/w 1 ? c/w .5 ? c/w 100 110 120 1.5 ? c/w no heatsink 90 60 30 0 15 30 60 75 45 20 40 60 80 load current [arms] max ambient temp. [ ? c] power dissipation 100 110 120 base plate temp [ ? c] 75a .5 ? c/w 95 1 ? c/w 120 80 40 0 20 40 80 0 60 20 40 60 80 load current [arms] max ambient temp. [ ? c] power dissipation 100 110 120 base plate temp [ ? c] 90a 1 ? c/w .4 ? c/w .2 ? c/w 90 .5 ? c/w 2 ? c/w .3 ? c/w 15 10 5 0 36 1215 9 20406080 load current [arms] max ambient temp. [ ? c] power dissipation base plate temp [ ? c] 15a 4 ? c/w 2 ? c/w 6 ? c/w no heatsink 112 124 116 120 c u rr e n t d e r a t in g c u r v es fastfax document no. 204 series pcv. rev. 041902 page 2 of 2 all dimensions are in inches (millimeters) s c rew t orque r equirement s : 6-32 screws - 10 in. lbs., 8-32 and 10-32 screws - 20in. lbs. (screws dry without grease.) proportional controller 12 4 3 ~ input output + -- wi r in g dia g r am ?2002 crydom corp, specifications subject to change without notice. for recommended applications and more information contact: usa: sales support (877) 502-5500 tech support (877) 702-7700 fax (619) 710-8540 crydom corp, 2320 paseo de las americas, ste. 201, san diego, ca 92154 email : sales@crydom.com web site: http://www.crydom.com uk: +44 (0)1202 365070  fax +44 (0)1202 365090 crydom international ltd., 7 cobham road, ferndown industrial estate, ferndown, dorset bh21 7pe, email : intsales@crydom.com. germany: +49 (0)180 3000 506


▲Up To Search▲   

 
Price & Availability of 10PCVXXX

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X